Siraj, Kiran; Khan, Hassan Abbas - In: Energy reports 6 (2020), pp. 944-951
-integrated photovoltaics and increasing electronic loads coupled with the decreasing prices of DC appliances. Unlike AC (110V, 60Hz, or 220 V … the system efficiency for a typical DC home at 48 V, 220 V, and 380 V DC and compare it with the 220 V AC using the … DC system at 220 V and 380 V is 4% and 10% more efficient than the AC 220 V system, respectively. Further, for 48 V DC …